FGR2-PE Wirelss Data Transceiver
LUM0024AB Rev A
VSWR Alarm Enable
Web Parameter: Reflected Power Enable check box in the SNMPTrap Limits section of the
SNMP page.
Network Type: Both
Default Setting: Disabled
Options: Disabled, Enabled
Description: Enables a trap for the reflected power of the transceiver. The trap condition is
present based on the settings in the VSWR Alarm Above parameter.
Voltage Alarm Above
Web Parameter: Voltage Alarm Above in the SNMPTrap Limits section of the SNMP page.
Network Type: Both
Default Setting: 30
Options: Any whole number between 6 and 30.
Description: If the Voltage Alarm Enable option is set to Enabled, a trap condition occurs
if the voltage goes above the value in this parameter.
Voltage Alarm Below
Web Parameter: Voltage Alarm Below in the SNMPTrap Limits section of the SNMP page.
Network Type: Both
Default Setting: 6
Options: Any whole number between 6 and 30 VDC.
Description: If the Voltage Alarm Enable option is set to Enabled, a trap condition occurs
if the voltage goes below the value in this parameter.
Voltage Alarm Enable
Web Parameter: Voltage Enable check box in the SNMPTrap Limits section of the SNMP
page.
Network Type: Both
Default Setting: Disabled
Options: Disabled, Enabled
Description: Enables a trap for the supply voltage of the transceiver. The trap condition is
present based on the settings in the Voltage Alarm Above and Voltage
Alarm Below parameters.