Self-Test Verify and Repair All
This function will verify communication with each of the devices on the two-wire. It does not
check the valve current nor does it check biSensor readings. If it finds a problem, it will attempt
to repair in the following repair order:
Repair valve biCoder to zone number assignments
Repair biSensor addressing
Repair pause device addressing
Repair air temperature sensor addressing
If you are troubleshooting two-wire problems (damaged and repaired), it is
a good idea to do a backup before doing search operations. Call Baseline
support for help and guidelines, 866-294-5847.
Manual Run Program
This dial position has three different operations
that can be performed. The first menu item can
be toggled between the program start/stop and
next start date by using the + or keys. Then use the NEXT/PREV keys to highlight the desired
program. Use the + or key to then change the value for the highlighted program.
1. A program that is stopped can be started (set to running). It will then run a full cycle
when the dial is turned to Auto/Run.
2. A program that is running can be
terminated (set to stopped).
3. A program that is using a Historical ET
Calendar can have its next run date
set. Programs that do not use this
mode have a fixed schedule and are
modified in the Day Intervals dial
position.