Baseline-systems BHM Series Hydrometer Bedienungsanleitung Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
26Hydrometers Operation and Maintenance Manual
Maintenance 1½” and 2” Models
1½” and 2” Hydrometers
The dis-assembly of the hydrometer is divided into the following assemblies:
Cover Assembly
Diaphragm/Stem and Base Assemblies
Inlet Spider/Strainer Assembly
Perform only those procedures necessary to inspect and replace parts as directed by the
troubleshooting procedures. It is recommended to replace the various o-rings and gaskets
during dis-assembly as well as to inspect certain other parts. All gaskets and o-rings must
be covered with grease prior to installation.
HYDROMETER COVER AND BASE ASSEMBLIES
Removal
Remove the register assembly as described on page 25.
Loosen and remove the upper bearing bolt (8) using the specially
sized box wrench. Model number: 03640-000071
Remove the upper bearing bolt o-ring (9) from the groove in the
underside of the bolt. Inspect and replace as necessary.
Loosen and remove the six cover screws (10), with the washers.
Lift the base and cover assemblies off of the hydrometer body (21).
Be especially careful not to damage the impeller.
Place the two assemblies upside down. Pull the impeller (30) up
and out.
Some force may be required to free the impeller.
Remove the magnet housing (31) from inside the cover assembly.
The magnet housing was freed from the impeller shaft during the
previous step.
Inspect the impeller and its components for signs of excessive wear
or damage.
Verify that the impeller shaft is straight. Replace as necessary.
Re-assembly
Carefully place the base and cover assemblies over the impeller shaft
(30).
Push the magnet housing (31) down over the top of the impeller shaft (which extends
through the hole in the cover). Tap the magnet housing with a hammer to ensure that it
is properly secured to
the shaft.
Place the base and cover assemblies onto the hydrometer body (21).
Replace and tighten the six cover screws (10).
Place the upper bearing bolt o-ring (9) into the groove on the underside of the bolt (8).
Screw in the upper bearing bolt “O” (8) using the specially sized
box wrench.
Replace the register assembly and cover as described on page 25.
Seitenansicht 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 51 52