10 • Hydrometers Operation and Maintenance Manual
Transducer Type
Transducer Type: Reed Switch and Photo Diode K Factors
Gallons per pulse 1 10 100 0.1 0.0053
Pulse per gallon 1 0.1 0.01 10 187.900
K factor 10.00 60.00 600.00 6000.00 6.00 0.319
Gallons per pulse 1 10 100 0.1 0.0085
Pulse per gallon 1 0.1 0.01 10 117.000
K factor 10.00 60.00 600.00 6000.00 6.00 0.5100
Gallons per pulse 1 10 100 0.1 0.0205
Pulse per gallon 1 0.1 0.01 10 48.710
K factor 10.00 60.00 600.00 6000.00 6.00 1.232
Gallons per pulse 1 10 100 1 0.0556
Pulse per gallon 1 0.1 0.01 10 17.993
K factor 10.00 60.00 600.00 6000.00 6.00 3.335
Gallons per pulse 10 100 1000 1 0.1741
Pulse per gallon 0.1 0.01 0.001 1 5.747
K factor 10.00 600.00 6000.00 60000.00 60.00 10.437
Gallons per pulse 10 100 1000 1 0.317
Pulse per gallon 0.1 0.01 0.001 1 3.152
K factor 10.00 600.00 6000.00 60000.00 60.00 19.036
Standard
Output
Optional Output PD PDH
Meter
Size
1½”
2”
3”
4”
6”
8”
Photo Diode (PD) and
Photo Diode High Frequency
Pulse (PDH)
Reed Switch (RS)
Note: Offset = 0 in all Netafim USA Water Meters
When entering K factors in controllers and/or data recorders please refer to the manufacturer’s
recommendations—some will require the number of gallons per pulse and others will require
the number of pulses per gallon. Some manufacturers will require a “K” and “offset” (for all
Netam USA Water Meters the offset = 0) where the K and offset are calculated using he fol-
lowing equation:
Freq = (GPM/K) – offset
Where:
Freq = pulse/second
GPM = gallons per minute
K = unit less constant specic to each hydrometer pulse output
Offset = correction factor (All Netam USA water meters have an offset = 0)
or:
K = 60/(pulse/gallon)